European Reference Laboratory for Glycohemoglobin study reaffirms EKF’s Quo-Test® meets HbA1c performance criteria

Cardiff, UK – 16th February 2017 – EKF Diagnostics, the global in vitro diagnostics company, announces that in a newly published paper [1] its Quo-Test® point-of-care (POC) hemoglobin A1c (HbA1c) analyzer has again been confirmed to meet International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) performance criteria. Using sigma-metrics data modelling, scientists from the European Reference Laboratory for Glycohemoglobin demonstrated that Quo-Test easily met IFCC accepted quality targets of >2 sigma at 10% total allowable error (TAE) at 48 mmol/mol HbA1c. This is essential for the effective monitoring of glycemic control in diabetes patients.

Under strict evaluation conditions, Quo-Test was not only shown to perform extremely well against routine laboratory analyzers, certified as secondary reference measurement procedures (SRMPs), but also when compared to six other POC HbA1c analyzers. The authors explained that in the laboratory, sigma-metrics is a quality management strategy that provides a universal benchmark for analytical performance - effectively placing all analyzers on a level playing field. Using sigma-metrics, analytical characteristics (bias and imprecision) are placed in the form of TAE within a framework of clinical requirements. An IFCC Task Force in 2015 advocated the use of sigma-metrics quality targets for HbA1c to standardize analytical quality at a global level [2].

This latest study [1] follows the release of critical evaluation data by the European Reference Laboratory for Glycohemoglobin published in a white paper in 2016 [3], which also demonstrated Quo-Test’s strong performance. In the white paper Quo-Test’s performance in sigma-metrics was very good. Sigma was shown to be >2 at 48mmol/mol and at an HbA1c value of 75 mmol/mol >4. Examining the CVs of all duplicates, one lot number even had a sigma of >6; this is a class-leading level of performance.

Notably, within the 2016 evaluation study, the boronate affinity fluorescence quenching technology employed by Quo-Test was demonstrated to maintain results consistency due to its ability to minimize the effects of hemoglobin variants. This compared well with laboratory-based HPLC systems. Quo-Test showed no interference of the common Hb-variants HbAS, HbAC, HbAD, HbAE, HBAJ, elevated A2 and HbF<8.6%.

“We are pleased that the European Reference Laboratory for Glycohemoglobin has reaffirmed that Quo-Test fully meets accepted global performance criteria for HbA1c analysis,” said Gavin Jones, Global Diabetes Product Manager, EKF Diagnostics. “We are extremely confident that our Quo-Test is one of the most accurate, easy-to-use and reliable HbA1c POC analyzers available, which is also unaffected by most hemoglobin variants.”

CE-marked for the monitoring of HbA1c in diabetes patients, Quo-Test is specifically designed for use in a POC setting, such as diabetes clinics and doctors’ surgeries. It is fully automated, measuring HbA1c from a 4 µL sample taken from a finger prick or venous whole blood. Results are available in four minutes within a measuring range of 4-15% A1c DCCT, and precision performance with a CV of 2.2% at 6.6% DCCT has been demonstrated [3].

For more information on EKF Diagnostics, please see www.ekfdiagnostics.com.

References:

  1. Lenters-Westra, E. & English, E. Understanding the use of sigma metrics in hemoglobin A1c analysis. Clin Lab Med 2017;37: 57-71.
  2. Weykamp, C., John, G., Gillery P. et al. on behalf of the IFCC Task Force on Implementation of HbA1c Standardization. Investigation of 2 models to set and evaluate quality targets for HbA1c: biological variation and sigma-metrics. Clin Chem 2015;61(5): 752-9.

Lenters-Westra, E. An evaluation of the Quo-Test performance against NGSP and sigma-metrics. 2016 White Paper available for download at: https://www.ekfdiagnostics.com/quo-test.html

Related

Invasive Aspergillosis Screening in COVID-19 & Critical Care Patients

IMMY sõna Aspergillus Galactomannan Lateral Flow Assay recommended by the European Confederation of ...

Read More >

HORIBA Medical launches D-Dimer reagent for Yumizen G Haemostasis range

New Yumizen GDDi 2 (D-Dimer) reagent kit for DVT and Pulmonary Embolism diagnosis

Read More >

FDA grants de novo designation for OGT’s AML/MDS FISH probes

Clearance enables accurate and easy-to-interpret AML and MDS detection with reduced validation burde...

Read More >

EKF POC HbA1c analyzer demonstrates excellent performance in international evaluation study

Quo-Lab meets strict international quality targets – confirming it fit for purpose for diabetes tes...

Read More >

New Non-Invasive Urine Test for Bladder Cancer Diagnosis Showcasing at BAUS 2018

Alpha Laboratories Ltd. (Eastleigh, UK) is delighted to have been appointed as the exclusive distrib...

Read More >

OGT pushes forward hybridisation-based targeted sequencing

Oxford, UK – 25 May 2017. Oxford Gene Technology (OGT), The Molecular Genetics Company, has made se...

Read More >